Helical CT image noise--analytical results.

G, Wang M W, Vannier  
Abstract

Helical CT is an important recent development in x-ray CT. In helical CT, planar projection sets are synthesized from raw projection data via interpolation. Among various interpolation schemes, linear interpolation is usually preferred due to its efficiency and performance. In this paper, image noise variance is derived for typical helical CT linear interpolation techniques, including the full scan (FS), under-scan (US), full scan with interpolation (FI), half-scan (HS), half-scan with interpolation (HI) and half-scan with extrapolation (HE) methods. Image noise deviation ratios of helical CT to conventional 360 degrees reconstruction (CR) are tabulated. These are consistent with previously reported simulation results. The theoretical results provide further understanding of helical CT noise performance. It is shown that helical CT image noise deviation is independent of transaxial position, proportional to the raw projection noise deviation, and not affected by the fan angle (approximately for the HE method). Also, helical CT image noise variance is proportional to the area under the square of the reconstruction filter.

Original Text (This is the original text for your reference.)

Helical CT image noise--analytical results.

Helical CT is an important recent development in x-ray CT. In helical CT, planar projection sets are synthesized from raw projection data via interpolation. Among various interpolation schemes, linear interpolation is usually preferred due to its efficiency and performance. In this paper, image noise variance is derived for typical helical CT linear interpolation techniques, including the full scan (FS), under-scan (US), full scan with interpolation (FI), half-scan (HS), half-scan with interpolation (HI) and half-scan with extrapolation (HE) methods. Image noise deviation ratios of helical CT to conventional 360 degrees reconstruction (CR) are tabulated. These are consistent with previously reported simulation results. The theoretical results provide further understanding of helical CT noise performance. It is shown that helical CT image noise deviation is independent of transaxial position, proportional to the raw projection noise deviation, and not affected by the fan angle (approximately for the HE method). Also, helical CT image noise variance is proportional to the area under the square of the reconstruction filter.

+More

Cite this article
APA

APA

MLA

Chicago

G, Wang M W, Vannier,.Helical CT image noise--analytical results.. 20 (6),1635-40.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel