137Cs dosimetry table for asymmetric source.

R, Waggener J, Lange J, Feldmeier P, Eagan S, Martin  
Abstract

A common 137Cs brachytherapy source has a 2-cm physical length and 1.38-cm active length. The active length is not symmetric with respect to the source center because one source end contains an eyelet. Current dose rate tables assume a symmetric source loading with respect to the source center. A computer program was written to calculate an asymmetric distribution using the manufacturers' source specifications. Corrections were made for attenuation and obliquity through the source materials. Dose rate values in cGy/h for a 137Cs source equivalent to 1 mg of 226Ra are shown as a function of the radius from the source center and angle from the source end containing the eyelet. Dose rate values in the table were confirmed by ferrous sulfate measurements using small volumes. The table values agree with published values at points more distant than a few cm and lying at an angle such that the asymmetry of the source loading has its minimum influence.

Original Text (This is the original text for your reference.)

137Cs dosimetry table for asymmetric source.

A common 137Cs brachytherapy source has a 2-cm physical length and 1.38-cm active length. The active length is not symmetric with respect to the source center because one source end contains an eyelet. Current dose rate tables assume a symmetric source loading with respect to the source center. A computer program was written to calculate an asymmetric distribution using the manufacturers' source specifications. Corrections were made for attenuation and obliquity through the source materials. Dose rate values in cGy/h for a 137Cs source equivalent to 1 mg of 226Ra are shown as a function of the radius from the source center and angle from the source end containing the eyelet. Dose rate values in the table were confirmed by ferrous sulfate measurements using small volumes. The table values agree with published values at points more distant than a few cm and lying at an angle such that the asymmetry of the source loading has its minimum influence.

+More

Cite this article
APA

APA

MLA

Chicago

R, Waggener J, Lange J, Feldmeier P, Eagan S, Martin,.137Cs dosimetry table for asymmetric source.. 16 (2),305-8.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel