Welcome to the IKCEST

IUCrJ | Vol.4, Issue.4 | 2017-07-19 | Pages

IUCrJ

Validation of experimental charge-density refinement strategies: when do we overfit?

  
Abstract

A cross-validation method is supplied to judge between various strategies in multipole refinement procedures. Its application enables straightforward detection of whether the refinement of additional parameters leads to an improvement in the model or an overfitting of the given data. For all tested data sets it was possible to prove that the multipole parameters of atoms in comparable chemical environments should be constrained to be identical. In an automated approach, this method additionally delivers parameter distributions of k different refinements. These distributions can be used for further error diagnostics, e.g. to detect erroneously defined parameters or incorrectly determined reflections. Visualization tools show the variation in the parameters. These different refinements also provide rough estimates for the standard deviation of topological parameters.

Original Text (This is the original text for your reference.)

Validation of experimental charge-density refinement strategies: when do we overfit?

A cross-validation method is supplied to judge between various strategies in multipole refinement procedures. Its application enables straightforward detection of whether the refinement of additional parameters leads to an improvement in the model or an overfitting of the given data. For all tested data sets it was possible to prove that the multipole parameters of atoms in comparable chemical environments should be constrained to be identical. In an automated approach, this method additionally delivers parameter distributions of k different refinements. These distributions can be used for further error diagnostics, e.g. to detect erroneously defined parameters or incorrectly determined reflections. Visualization tools show the variation in the parameters. These different refinements also provide rough estimates for the standard deviation of topological parameters.

+More

Cite this article
APA

APA

MLA

Chicago

,.Validation of experimental charge-density refinement strategies: when do we overfit?. 4 (4),.

References

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel