Correlation between pixel values in a cone-beam computed tomographic scanner and the computed tomographic values in a multidetector row computed tomographic scanner.

Jira, Chindasombatjaroen Naoya, Kakimoto Hiroaki, Shimamoto Shumei, Murakami Souhei, Furukawa  
Abstract

The study's objectives were to investigate the correlation between pixel values obtained from a cone-beam computed tomographic (CBCT) scanner and the computed tomographic (CT) values from a multidetector row CT scanner and to determine whether they have a linear relationship at various tube voltages and tube currents.A phantom with different concentrations of contrast medium at the center of a multidetector row CT and a CBCT scanner was scanned at various imaging parameters. Computed tomographic values and pixel values were measured using ImageJ. Regression analysis was performed, as well as correlation tests with a Pearson correlation coefficient.A significant correlation between pixel values and the CT values of the same specimen was observed (P < 0.0001), and a linear relationship was found between the values from the 2 scanners at each parameter.A high correlation and linear relationship between the CT values and pixel values were found at each parameter. Therefore, linear functions can be used to convert a pixel value from the CBCT machine used in this study to the CT values.

Original Text (This is the original text for your reference.)

Correlation between pixel values in a cone-beam computed tomographic scanner and the computed tomographic values in a multidetector row computed tomographic scanner.

The study's objectives were to investigate the correlation between pixel values obtained from a cone-beam computed tomographic (CBCT) scanner and the computed tomographic (CT) values from a multidetector row CT scanner and to determine whether they have a linear relationship at various tube voltages and tube currents.A phantom with different concentrations of contrast medium at the center of a multidetector row CT and a CBCT scanner was scanned at various imaging parameters. Computed tomographic values and pixel values were measured using ImageJ. Regression analysis was performed, as well as correlation tests with a Pearson correlation coefficient.A significant correlation between pixel values and the CT values of the same specimen was observed (P < 0.0001), and a linear relationship was found between the values from the 2 scanners at each parameter.A high correlation and linear relationship between the CT values and pixel values were found at each parameter. Therefore, linear functions can be used to convert a pixel value from the CBCT machine used in this study to the CT values.

+More

Cite this article
APA

APA

MLA

Chicago

Jira, Chindasombatjaroen Naoya, Kakimoto Hiroaki, Shimamoto Shumei, Murakami Souhei, Furukawa,.Correlation between pixel values in a cone-beam computed tomographic scanner and the computed tomographic values in a multidetector row computed tomographic scanner.. 35 (5),662-5.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel