Heating behaviour in English homes: An assessment of indirect calculation methods

T. Kane   S.K. Firth   T.M. Hassan   V. Dimitriou  
Abstract

Heating behaviours, such as timer and room thermostat settings, are a key influencing factor in energy demand in homes. However they are difficult to measure directly in existing housing with standard heating systems and controls. To overcome this, several indirect methods have been developed in previous research which estimate heating behaviours using sensor measurements of temperatures and energy demands in the home. This work assesses seven of these heating behaviour indirect calculation methods through a comparative study based on sensor data recorded in 20 English homes over a five month period. The results show that methods based on room air temperatures estimate mean daily heating durations between 6.7 and 11.4hours per day, based on radiator surface temperatures between 2.9 and 3.3h per day and based on gas consumption for 4.4h per day. Estimated thermostat setting based on peak whole house temperature ranged between 20.3°C and 20.8°C but a 5°C temperature range was found when applying the methods to different room temperatures. Of the methods tested, the radiator surface temperature method was found to be the most appropriate for calculating heating behaviours over time and a set of guidelines for the future application of indirect heating behaviour calculation methods is provided. The findings highlight the need for future studies to directly measure heating behaviours in homes in order to further improve the development of indirect heating behaviour calculation methods.

Original Text (This is the original text for your reference.)

Heating behaviour in English homes: An assessment of indirect calculation methods

Heating behaviours, such as timer and room thermostat settings, are a key influencing factor in energy demand in homes. However they are difficult to measure directly in existing housing with standard heating systems and controls. To overcome this, several indirect methods have been developed in previous research which estimate heating behaviours using sensor measurements of temperatures and energy demands in the home. This work assesses seven of these heating behaviour indirect calculation methods through a comparative study based on sensor data recorded in 20 English homes over a five month period. The results show that methods based on room air temperatures estimate mean daily heating durations between 6.7 and 11.4hours per day, based on radiator surface temperatures between 2.9 and 3.3h per day and based on gas consumption for 4.4h per day. Estimated thermostat setting based on peak whole house temperature ranged between 20.3°C and 20.8°C but a 5°C temperature range was found when applying the methods to different room temperatures. Of the methods tested, the radiator surface temperature method was found to be the most appropriate for calculating heating behaviours over time and a set of guidelines for the future application of indirect heating behaviour calculation methods is provided. The findings highlight the need for future studies to directly measure heating behaviours in homes in order to further improve the development of indirect heating behaviour calculation methods.

+More

Cite this article
APA

APA

MLA

Chicago

T. Kane, S.K. Firth, T.M. Hassan, V. Dimitriou,.Heating behaviour in English homes: An assessment of indirect calculation methods. 148 (0),.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel