Journal of Turbomachinery | Vol.139, Issue.10 | | Pages
Aerothermal Performance of a Nozzle Vane Cascade With a Generic Nonuniform Inlet Flow Condition—Part II: Influence of Purge and Film Cooling Injection
In the present paper, the influence of the presence of an inlet flow nonuniformity on the aerodynamic and thermal performance of a film cooled linear nozzle vane cascade is fully assessed. Tests have been carried out with platform cooling, with coolant ejected through a slot located upstream of the leading edge. Cooling air is also ejected through a row of cylindrical holes located upstream of the slot, simulating a combustor cooling system. An obstruction was installed upstream of the cascade at variable tangential and axial position to generate a flow nonuniformity. The cascade was tested at a high inlet turbulence intensity level (Tu1 = 9%) and at a constant inlet Mach number of 0.12 and nominal cooling condition. Aerothermal characterization of vane platform was obtained through five-hole probe and end wall adiabatic film cooling effectiveness measurements. Results show a relevant negative impact of inlet flow nonuniformity on the cooled cascade aerodynamic and thermal performance. Higher film cooling effectiveness and lower aerodynamic losses are obtained when the inlet flow nonuniformity is located at midpitch, while lower effectiveness and higher losses are obtained when it is aligned to the vane leading edge. Moving the nonuniformity axially or changing its blockage only marginally influences the platform thermal protection.
Original Text (This is the original text for your reference.)
Aerothermal Performance of a Nozzle Vane Cascade With a Generic Nonuniform Inlet Flow Condition—Part II: Influence of Purge and Film Cooling Injection
In the present paper, the influence of the presence of an inlet flow nonuniformity on the aerodynamic and thermal performance of a film cooled linear nozzle vane cascade is fully assessed. Tests have been carried out with platform cooling, with coolant ejected through a slot located upstream of the leading edge. Cooling air is also ejected through a row of cylindrical holes located upstream of the slot, simulating a combustor cooling system. An obstruction was installed upstream of the cascade at variable tangential and axial position to generate a flow nonuniformity. The cascade was tested at a high inlet turbulence intensity level (Tu1 = 9%) and at a constant inlet Mach number of 0.12 and nominal cooling condition. Aerothermal characterization of vane platform was obtained through five-hole probe and end wall adiabatic film cooling effectiveness measurements. Results show a relevant negative impact of inlet flow nonuniformity on the cooled cascade aerodynamic and thermal performance. Higher film cooling effectiveness and lower aerodynamic losses are obtained when the inlet flow nonuniformity is located at midpitch, while lower effectiveness and higher losses are obtained when it is aligned to the vane leading edge. Moving the nonuniformity axially or changing its blockage only marginally influences the platform thermal protection.
+More
air cooled cascade aerodynamic and thermal performance inlet mach number inlet turbulence intensity level inlet flow nonuniformity platform thermal protection cooling condition aerothermal characterization of tangential and fivehole probe and end wall adiabatic film cooling effectiveness obstruction film cooled linear nozzle vane cascade aerodynamic losses