Welcome to the IKCEST

Journal of Constructional Steel Research | Vol.133, Issue.0 | | Pages

Journal of Constructional Steel Research

Seismic performance of Z-type cantilever beam splices of column–tree connection

Xue-chun Liu   Ai-lin Zhang   Zhi-peng Guo  
Abstract

Three types of Z-type cantilever beam splices of the column–tree connection have been designed, which dissipate energy through plastic hinges: weakened beam splice, beam splice with a reduced beam and beam splice with a reduced cantilever beam. The weakened beam splice mainly dissipates energy through slipping, the beam splice with a reduced beam utilizes the slip of the splice and plastic deformation of the reduced beam section to dissipate energy, and beam splice with a reduced cantilever beam mainly utilizes plastic deformation of the reduced cantilever beam to dissipate energy. The behavior of three types of beam splices of the column–tree connection is investigated and discussed based on both tests and finite element analyses. The results show that the three types of specimens have good ductility performance and plastic rotation capacity. The energy dissipation capacity of the beam splice with a reduced cantilever beam is better than that of the weakened beam splice. The energy dissipation capacity of the beam splice with a reduced beam section is between the two splices. Simplified computation formulas and seismic design requirements for beam splices are proposed, and the computation results are in good agreement with those of the experiments.

Original Text (This is the original text for your reference.)

Seismic performance of Z-type cantilever beam splices of column–tree connection

Three types of Z-type cantilever beam splices of the column–tree connection have been designed, which dissipate energy through plastic hinges: weakened beam splice, beam splice with a reduced beam and beam splice with a reduced cantilever beam. The weakened beam splice mainly dissipates energy through slipping, the beam splice with a reduced beam utilizes the slip of the splice and plastic deformation of the reduced beam section to dissipate energy, and beam splice with a reduced cantilever beam mainly utilizes plastic deformation of the reduced cantilever beam to dissipate energy. The behavior of three types of beam splices of the column–tree connection is investigated and discussed based on both tests and finite element analyses. The results show that the three types of specimens have good ductility performance and plastic rotation capacity. The energy dissipation capacity of the beam splice with a reduced cantilever beam is better than that of the weakened beam splice. The energy dissipation capacity of the beam splice with a reduced beam section is between the two splices. Simplified computation formulas and seismic design requirements for beam splices are proposed, and the computation results are in good agreement with those of the experiments.

+More

Cite this article
APA

APA

MLA

Chicago

Xue-chun Liu,Ai-lin Zhang, Zhi-peng Guo,.Seismic performance of Z-type cantilever beam splices of column–tree connection. 133 (0),.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel