Journal of orthopaedic trauma | Vol.14, Issue.7 | | Pages 505-8

Journal of orthopaedic trauma

Insertion force measurement of cervical traction tongs: a biomechanical study.

K, Littleton A, Curcin V P, Novak S M, Belkoff  
Abstract

To measure the insertion forces for various cervical traction tong pins and the force required to penetrate cadaveric skull specimens.Cadaveric study testing tong pin forces.Insertion force and pin indicator displacement were measured in three tongs from each of three manufacturers (PMT, Depuy Ace, Gardner-Wells) after tightening pins per the manufacturer's recommendations and beyond. The force required for skull penetration was measured by driving each pin into cadaveric temporal specimens until the specimen failed or was penetrated.Forces generated at the recommended pin settings were: PMT, 141 +/- 12 newtons; Ace, 0 +/- 0 newtons; Gardner-Wells, 132 +/- 9 newtons. The Ace tong required 1.0-millimeter indicator protrusion beyond manufacturer's recommended setting before generating clinically significant forces (120 +/- 8 newtons). Unlike the PMT and Ace pins, overtightening of the Gardner-Wells pins (by as little as 0.3 mm beyond recommended indicator displacement) resulted in substantially larger pin force (>448 newtons). Average failure loads of the temporal bone specimens were: PMT, 721 +/- 298 newtons; Ace, 636 +/- 351 newtons; Gardner-Wells, 965 +/- 227 newtons.Although pin forces generated at the recommended end point for PMT and Gardner-Wells tongs appear safe, insufficient force was generated for Ace tongs. Furthermore, overtightening of the Gardner-Wells pins generated loads in excess of those that may be required to penetrate the skull.

Original Text (This is the original text for your reference.)

Insertion force measurement of cervical traction tongs: a biomechanical study.

To measure the insertion forces for various cervical traction tong pins and the force required to penetrate cadaveric skull specimens.Cadaveric study testing tong pin forces.Insertion force and pin indicator displacement were measured in three tongs from each of three manufacturers (PMT, Depuy Ace, Gardner-Wells) after tightening pins per the manufacturer's recommendations and beyond. The force required for skull penetration was measured by driving each pin into cadaveric temporal specimens until the specimen failed or was penetrated.Forces generated at the recommended pin settings were: PMT, 141 +/- 12 newtons; Ace, 0 +/- 0 newtons; Gardner-Wells, 132 +/- 9 newtons. The Ace tong required 1.0-millimeter indicator protrusion beyond manufacturer's recommended setting before generating clinically significant forces (120 +/- 8 newtons). Unlike the PMT and Ace pins, overtightening of the Gardner-Wells pins (by as little as 0.3 mm beyond recommended indicator displacement) resulted in substantially larger pin force (>448 newtons). Average failure loads of the temporal bone specimens were: PMT, 721 +/- 298 newtons; Ace, 636 +/- 351 newtons; Gardner-Wells, 965 +/- 227 newtons.Although pin forces generated at the recommended end point for PMT and Gardner-Wells tongs appear safe, insufficient force was generated for Ace tongs. Furthermore, overtightening of the Gardner-Wells pins generated loads in excess of those that may be required to penetrate the skull.

+More

Cite this article
APA

APA

MLA

Chicago

K, Littleton A, Curcin V P, Novak S M, Belkoff,.Insertion force measurement of cervical traction tongs: a biomechanical study.. 14 (7),505-8.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel