La Radiologia medica | Vol.106, Issue.1-2 | | Pages 94-102

La Radiologia medica

Imaging characteristics evaluation of a digital radiography system.

Luca, Moro Armando, Pannella Chiara, Bassetti Daniele, Fantinato Maurizia, Baldi Giuseppe, Bertoli  
Abstract

To evaluate the physical imaging characteristics of an indirect digital radiography system used for general radiography.The performance of the two 41x41 cm2 CsI:Tl/a-Si flat-panel detectors of a GE-Revolution XR/d digital radiography system was evaluated. Signal uniformity, dose linearity, pre-sampling and expectation Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE) were measured at 70 kVp, varying the incident dose levels, according to IEC 62220-1. The effects of anti-scatter grid on NPS were also studied.Both detectors have a limiting spatial resolution of 2.5 lp/mm set by the pixel pitch. Raw images demonstrated fairly good uniformity, excellent repeatability and linearity. Without the grid in the anode-cathode direction, for an 8 mGy incident dose, both pre-sampling and EMTF were greater than 0.5 and 0.2 for spatial frequencies of 1 and 2 lp/mm, respectively. At the same dose and frequencies, for one detector, DQE was greater than 0.61 and 0.20; for the other one, DQE was greater than 0.41 and 0.18.The two detector panels showed different DQE curves. Namely, the table detector DQE was excellent at low dose levels but its performance appeared to degrade with increasing doses, both in mean values and in shape, whereas the wall stand detector DQE appeared to depend less strongly on dose. In any case, the DQE values obtained from this study were higher than those reported in the literature for storage phosphor Computed Radiography systems.

Original Text (This is the original text for your reference.)

Imaging characteristics evaluation of a digital radiography system.

To evaluate the physical imaging characteristics of an indirect digital radiography system used for general radiography.The performance of the two 41x41 cm2 CsI:Tl/a-Si flat-panel detectors of a GE-Revolution XR/d digital radiography system was evaluated. Signal uniformity, dose linearity, pre-sampling and expectation Modulation Transfer Function (MTF), Noise Power Spectrum (NPS) and Detective Quantum Efficiency (DQE) were measured at 70 kVp, varying the incident dose levels, according to IEC 62220-1. The effects of anti-scatter grid on NPS were also studied.Both detectors have a limiting spatial resolution of 2.5 lp/mm set by the pixel pitch. Raw images demonstrated fairly good uniformity, excellent repeatability and linearity. Without the grid in the anode-cathode direction, for an 8 mGy incident dose, both pre-sampling and EMTF were greater than 0.5 and 0.2 for spatial frequencies of 1 and 2 lp/mm, respectively. At the same dose and frequencies, for one detector, DQE was greater than 0.61 and 0.20; for the other one, DQE was greater than 0.41 and 0.18.The two detector panels showed different DQE curves. Namely, the table detector DQE was excellent at low dose levels but its performance appeared to degrade with increasing doses, both in mean values and in shape, whereas the wall stand detector DQE appeared to depend less strongly on dose. In any case, the DQE values obtained from this study were higher than those reported in the literature for storage phosphor Computed Radiography systems.

+More

Cite this article
APA

APA

MLA

Chicago

Luca, Moro Armando, Pannella Chiara, Bassetti Daniele, Fantinato Maurizia, Baldi Giuseppe, Bertoli,.Imaging characteristics evaluation of a digital radiography system.. 106 (1-2),94-102.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel